2600W
Dual Input (AC/DC-DC)
Redundant
Input voltage |
AC input: 180 - 264Vac DC input: 180 - 300Vdc |
Input frequency | 47 - 63Hz |
Input current | 200-240Vac |
Voltage | +12V (200-240Vac) / (240Vdc) | +12Vsb |
Regulation | ±5% | ±5% |
Max Load | 216A | 4.0A |
Ripple & Noise | 150mVp-p | 150mVp-p |
Hold-up time | 10-11.2ms @@ 70% load |
Efficiency | At least 96% @@ 50% load |
MTBF | 400,000 hours @ 100% load at 30°C |
Temperature |
Operating: 0-50°C Non-operating: -40°C to 70°C |
Altitude |
Operating: 16,500 feet (5,000 meters) Non-operating: 50,000 feet (15,200 meters) |
Relative humidity |
Operating: 5% to 90% RH, non-condensing Non-operating: 5% to 95% RH, non-condensing |