CPR-1621-6M1

1600W

Dual Input (AC/DC-DC)

Redundant

Type
  • Dual Input (AC/DC-DC)
Dimensions
  • 203 X 73.5 X 40 (D x W x H)
Max Power
  • 1600W @ 180 - 240Vac
  • 1000W @ 100 - 140Vac
80 PLUS
  • 80 plus Titanium
Key Features
  • 80 PLUS Titanium
  • Support PMBus 1.2
  • Internal ORing
  • N+1 Redundant
  • Digital Power Supply
  • Cold Redundancy
  • Smart Ride Through
  • Black Box Recorder
  • Automatic Firmware Update
  • High Power Density
  • Active Power Factor Correction
  • Closed Loop System Protection (CLST)
Input
Input voltage 90 - 264Vac
Input frequency 47 - 63Hz
Input current 100 - 140V / 13 - 9.0A
180 - 240V / 11 - 8.0A
Output
Voltage +12V +12Vsb
Regulation ±5% ±5%
Max Load 1000W : 83A
1600W : 133A
3.5A
Ripple & Noise 120mVp-p 120mVp-p
General
Hold-up time 11ms @ 70% Load
Efficiency At least 96% @ 50% load
MTBF 50,000 hours at 50°C
Environmental
Temperature Operating: 0 to 50°C
Altitude Operating: 10,000 feet
Relative humidity Operating: 20% to 85% RH
UL, cUL, BSMI, CQC, CB, CE, FCC Class A, CISPR Class A, ROHS,